IDI version 26.8 is now available.  Click here for details: IDI Updates.

SVC029 - A usage record cannot guide by IMSI to an ambiguous service

Prev Next

Override NOT allowed

Name

A usage record cannot guide by IMSI to an ambiguous service.

Common Cause

This IMSI is assigned to multiple services in CostGuard and the active dates of these services overlap, so it isn’t possible to determine which of these to guide this usage to.

Common Resolution(s)

Action you can take to resolve the problem:

  • Fix the IMSI overlap by correcting the effective and/or disconnect dates of the incorrect occurrence of the service.

Details

An IMSI may be assigned to services in CostGuard multiple times, but each occurrence must have an effective/disconnect date range that doesn’t overlap with any other. In this case, an IMSI is present at least twice in the system, and the date ranges of these instances overlap. It is likely that some conversion or migration error caused this, because the system prevents users from making this mistake.